Image |
Référence |
Fabricant |
Description |
paquet |
Stock |
Quantité |
Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Polarization | Mounting Type | Package / Case |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HARTING |
SENSOR CURRENT HALL 2000A AC
|
paquet: Module, Single Pass Through |
Stock3 418 |
|
Hall Effect, Closed Loop | 2000A | 1 | Ratiometric, Voltage | - | - | ±0.1% | ±0.3% | 15V | 1µs | 33mA | -40°C ~ 85°C | Bidirectional | Chassis Mount | Module, Single Pass Through |
||
HARTING |
SENSOR CURRENT HALL 1000A AC
|
paquet: Module, Single Pass Through |
Stock8 370 |
|
Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.4% | 15 V ~ 24 V | 1µs | 28mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
||
HARTING |
SENSOR CURRENT HALL 500A AC
|
paquet: Module, Single Pass Through |
Stock4 662 |
|
Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±0.1% | ±1% | 15 V ~ 24 V | 1µs | 35mA | -40°C ~ 85°C | Bidirectional | Chassis Mount | Module, Single Pass Through |
||
HARTING |
SENSOR CURRENT HALL 200A AC
|
paquet: Module, Single Pass Through |
Stock6 570 |
|
Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.8% | 15V | 1µs | 20mA | -40°C ~ 85°C | Bidirectional | Chassis Mount | Module, Single Pass Through |
||
HARTING |
SENSOR CURRENT HALL 200A AC
|
paquet: Module, Single Pass Through |
Stock6 012 |
|
Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.8% | 12 V ~ 15 V | 1µs | 20mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
||
HARTING |
SENSOR CURRENT HALL 2000A AC
|
paquet: Module, Single Pass Through |
Stock8 910 |
|
Hall Effect, Closed Loop | 2000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.3% | 15 V ~ 24 V | 1µs | 33mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
||
HARTING |
SENSOR CURRENT HALL 1000A AC
|
paquet: Module, Single Pass Through |
Stock6 516 |
|
Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.4% | 15 V ~ 24 V | 1µs | 28mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
||
HARTING |
SENSOR CURRENT HALL 500A AC
|
paquet: Module, Single Pass Through |
Stock6 084 |
|
Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.6% | 15 V ~ 24 V | 1µs | 24mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |
||
HARTING |
SENSOR CURRENT HALL 300A AC
|
paquet: Module, Single Pass Through |
Stock7 164 |
|
Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.5% | 15V | 1µs | 25mA | -40°C ~ 85°C | Bidirectional | Panel Mount | Module, Single Pass Through |