Produits Phoenix Contact - Transducteurs de courant | Heisener Electronics
Contactez nous
SalesDept@heisener.com 86-755-83210559-802
Language Translation

* Please refer to the English Version as our Official Version.

Produits Phoenix Contact - Transducteurs de courant

Dossiers 13
Page  1/1
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Sensor Type
Current - Sensing
Number of Channels
Output
Sensitivity
Frequency
Linearity
Accuracy
Voltage - Supply
Response Time
Current - Supply (Max)
Operating Temperature
Polarization
Mounting Type
Package / Case
2814663
Phoenix Contact

SENSOR CURRENT HALL 55A AC/DC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Open Loop
  • Current - Sensing: 55A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage and Current
  • Sensitivity: -
  • Frequency: 15Hz ~ 400Hz
  • Linearity: -
  • Accuracy: ±0.5%
  • Voltage - Supply: 20 V ~ 30 V
  • Response Time: 330ms (AC), 40ms (DC)
  • Current - Supply (Max): 50mA
  • Operating Temperature: -20°C ~ 60°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock5 508
Hall Effect, Open Loop
55A
1
Ratiometric, Voltage and Current
-
15Hz ~ 400Hz
-
±0.5%
20 V ~ 30 V
330ms (AC), 40ms (DC)
50mA
-20°C ~ 60°C
Bidirectional
DIN Rail
Module
2814650
Phoenix Contact

SENSOR CURRENT HALL 11A AC/DC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Open Loop
  • Current - Sensing: 11A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage and Current
  • Sensitivity: -
  • Frequency: 15Hz ~ 400Hz
  • Linearity: -
  • Accuracy: ±0.5%
  • Voltage - Supply: 20 V ~ 30 V
  • Response Time: 330ms (AC), 40ms (DC)
  • Current - Supply (Max): 50mA
  • Operating Temperature: -20°C ~ 60°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock7 290
Hall Effect, Open Loop
11A
1
Ratiometric, Voltage and Current
-
15Hz ~ 400Hz
-
±0.5%
20 V ~ 30 V
330ms (AC), 40ms (DC)
50mA
-20°C ~ 60°C
Bidirectional
DIN Rail
Module
2814647
Phoenix Contact

SENSOR CURRENT HALL 55A AC/DC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Open Loop
  • Current - Sensing: 55A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage and Current
  • Sensitivity: -
  • Frequency: 15Hz ~ 400Hz
  • Linearity: -
  • Accuracy: ±0.5%
  • Voltage - Supply: 20 V ~ 30 V
  • Response Time: 330ms (AC), 40ms (DC)
  • Current - Supply (Max): 40mA
  • Operating Temperature: -20°C ~ 60°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock2 826
Hall Effect, Open Loop
55A
1
Ratiometric, Voltage and Current
-
15Hz ~ 400Hz
-
±0.5%
20 V ~ 30 V
330ms (AC), 40ms (DC)
40mA
-20°C ~ 60°C
Bidirectional
DIN Rail
Module
2814634
Phoenix Contact

SENSOR CURRENT HALL 11A AC/DC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Open Loop
  • Current - Sensing: 11A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage and Current
  • Sensitivity: -
  • Frequency: 15Hz ~ 400Hz
  • Linearity: -
  • Accuracy: ±0.5%
  • Voltage - Supply: 20 V ~ 30 V
  • Response Time: 330ms (AC), 40ms (DC)
  • Current - Supply (Max): 40mA
  • Operating Temperature: -20°C ~ 60°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock5 958
Hall Effect, Open Loop
11A
1
Ratiometric, Voltage and Current
-
15Hz ~ 400Hz
-
±0.5%
20 V ~ 30 V
330ms (AC), 40ms (DC)
40mA
-20°C ~ 60°C
Bidirectional
DIN Rail
Module
2902990
Phoenix Contact

PACT RCP-4000A-1A

  • For Measuring: -
  • Sensor Type: -
  • Current - Sensing: -
  • Number of Channels: -
  • Output: -
  • Sensitivity: -
  • Frequency: -
  • Linearity: -
  • Accuracy: -
  • Voltage - Supply: -
  • Response Time: -
  • Current - Supply (Max): -
  • Operating Temperature: -
  • Polarization: -
  • Mounting Type: -
  • Package / Case: -
paquet: -
Stock3 834
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2904890
Phoenix Contact

PACT RCP-D95

  • For Measuring: AC
  • Sensor Type: Transformer w/Conditioning
  • Current - Sensing: -
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 40Hz ~ 20kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.2%
  • Voltage - Supply: -
  • Response Time: -
  • Current - Supply (Max): -
  • Operating Temperature: -30°C ~ 80°C
  • Polarization: Bidirectional
  • Mounting Type: Screw
  • Package / Case: Module
paquet: Module
Stock8 982
Transformer w/Conditioning
-
1
Ratiometric, Voltage
-
40Hz ~ 20kHz
±0.1%
±0.2%
-
-
-
-30°C ~ 80°C
Bidirectional
Screw
Module
2904892
Phoenix Contact

PACT RCP-D190

  • For Measuring: AC
  • Sensor Type: Transformer w/Conditioning
  • Current - Sensing: -
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 40Hz ~ 20kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.2%
  • Voltage - Supply: -
  • Response Time: -
  • Current - Supply (Max): -
  • Operating Temperature: -30°C ~ 80°C
  • Polarization: Bidirectional
  • Mounting Type: Screw
  • Package / Case: Module
paquet: Module
Stock3 276
Transformer w/Conditioning
-
1
Ratiometric, Voltage
-
40Hz ~ 20kHz
±0.1%
±0.2%
-
-
-
-30°C ~ 80°C
Bidirectional
Screw
Module
2904891
Phoenix Contact

PACT RCP-D140

  • For Measuring: AC
  • Sensor Type: Transformer w/Conditioning
  • Current - Sensing: -
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 40Hz ~ 20kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.2%
  • Voltage - Supply: -
  • Response Time: -
  • Current - Supply (Max): -
  • Operating Temperature: -30°C ~ 80°C
  • Polarization: Bidirectional
  • Mounting Type: Screw
  • Package / Case: Module
paquet: Module
Stock8 802
Transformer w/Conditioning
-
1
Ratiometric, Voltage
-
40Hz ~ 20kHz
±0.1%
±0.2%
-
-
-
-30°C ~ 80°C
Bidirectional
Screw
Module
2814359
Phoenix Contact

CURRENT MEASURING TRANSDUCER

  • For Measuring: AC
  • Sensor Type: Transformer w/Conditioning
  • Current - Sensing: 1A, 5A (Selectable)
  • Number of Channels: 1
  • Output: Ratiometric, 0 V ~ 10 V, 0 ~ 20mA
  • Sensitivity: -
  • Frequency: 45Hz ~ 60Hz
  • Linearity: -
  • Accuracy: -
  • Voltage - Supply: -
  • Response Time: -
  • Current - Supply (Max): -
  • Operating Temperature: -25°C ~ 65°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock6 786
Transformer w/Conditioning
1A, 5A (Selectable)
1
Ratiometric, 0 V ~ 10 V, 0 ~ 20mA
-
45Hz ~ 60Hz
-
-
-
-
-
-25°C ~ 65°C
Bidirectional
DIN Rail
Module
2904923
Phoenix Contact

PACT RCP-4000A-1A-D190

  • For Measuring: AC
  • Sensor Type: Transformer w/Conditioning
  • Current - Sensing: 100A ~ 4000A (Selectable)
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 10Hz ~ 5kHz
  • Linearity: ±0.5%
  • Accuracy: ±1%
  • Voltage - Supply: 24V
  • Response Time: -
  • Current - Supply (Max): -
  • Operating Temperature: 20°C ~ 70°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock4 806
Transformer w/Conditioning
100A ~ 4000A (Selectable)
1
Ratiometric, Voltage
-
10Hz ~ 5kHz
±0.5%
±1%
24V
-
-
20°C ~ 70°C
Bidirectional
DIN Rail
Module
2904922
Phoenix Contact

PACT RCP-4000A-1A-D140

  • For Measuring: AC
  • Sensor Type: Transformer w/Conditioning
  • Current - Sensing: 100A ~ 4000A (Selectable)
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 10Hz ~ 5kHz
  • Linearity: ±0.5%
  • Accuracy: ±1%
  • Voltage - Supply: 24V
  • Response Time: -
  • Current - Supply (Max): -
  • Operating Temperature: 20°C ~ 70°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock3 906
Transformer w/Conditioning
100A ~ 4000A (Selectable)
1
Ratiometric, Voltage
-
10Hz ~ 5kHz
±0.5%
±1%
24V
-
-
20°C ~ 70°C
Bidirectional
DIN Rail
Module
2814744
Phoenix Contact

SENSOR CURRENT HALL 55A AC/DC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Open Loop
  • Current - Sensing: 55A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage and Current
  • Sensitivity: -
  • Frequency: 15Hz ~ 400Hz
  • Linearity: -
  • Accuracy: ±0.5%
  • Voltage - Supply: 20 V ~ 30 V
  • Response Time: 330ms (AC), 40ms (DC)
  • Current - Supply (Max): 50mA
  • Operating Temperature: -20°C ~ 60°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock8 154
Hall Effect, Open Loop
55A
1
Ratiometric, Voltage and Current
-
15Hz ~ 400Hz
-
±0.5%
20 V ~ 30 V
330ms (AC), 40ms (DC)
50mA
-20°C ~ 60°C
Bidirectional
DIN Rail
Module
2904921
Phoenix Contact

PACT RCP-4000A-1A-D95

  • For Measuring: AC
  • Sensor Type: Transformer w/Conditioning
  • Current - Sensing: 100A ~ 4000A (Selectable)
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 10Hz ~ 5kHz
  • Linearity: ±0.5%
  • Accuracy: ±1%
  • Voltage - Supply: 24V
  • Response Time: -
  • Current - Supply (Max): -
  • Operating Temperature: 20°C ~ 70°C
  • Polarization: Bidirectional
  • Mounting Type: DIN Rail
  • Package / Case: Module
paquet: Module
Stock7 470
Transformer w/Conditioning
100A ~ 4000A (Selectable)
1
Ratiometric, Voltage
-
10Hz ~ 5kHz
±0.5%
±1%
24V
-
-
20°C ~ 70°C
Bidirectional
DIN Rail
Module