Page 5 - Produits Bourns Inc. - Tubes à éclateur à gaz (GDT) | Heisener Electronics
Contactez nous
SalesDept@heisener.com +86-755-83210559-827
Language Translation

* Please refer to the English Version as our Official Version.

Produits Bourns Inc. - Tubes à éclateur à gaz (GDT)

Dossiers 1 289
Page  5/47
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
2036-60-BLF
Bourns Inc.

GDT 600V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock9 564
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, Radial Bend
2026-09-CLF
Bourns Inc.

GDT 90V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
paquet: Axial Cylinder, 3 Lead (T-Shape)
Stock12 024
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
hot 2036-07-SM
Bourns Inc.

GDT 75V 20% 10KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 75V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock11 760
10000A (10kA)
±20%
3
No
Surface Mount
3-SMD Cylinder Square End
2026-09-A1
Bourns Inc.

GDT 90V 20% 20KA

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
paquet: Cylinder No Lead, 3 Terminal
Stock9 480
20000A (20kA)
±20%
3
No
User Defined
Cylinder No Lead, 3 Terminal
2036-23-SMLF
Bourns Inc.

GDT 230V 20% 10KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock19 152
10000A (10kA)
±20%
3
No
Surface Mount
3-SMD Cylinder Square End
2028-25-C2LF
Bourns Inc.

GDT 250V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock17 844
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2046-42-C2LF
Bourns Inc.

GDT 420V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock6 360
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2046-35-C2LF
Bourns Inc.

GDT 350V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock6 972
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2056-09-B2LF
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock17 376
5000A (5kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2046-23-C2LF
Bourns Inc.

GDT 230V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock16 476
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2046-09-C2LF
Bourns Inc.

GDT 90V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock20 616
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2095-160-BLF
Bourns Inc.

GDT 1600V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock7 188
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2027-47-CLF
Bourns Inc.

GDT 470V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock9 840
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-23-B
Bourns Inc.

GDT 230V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock8 004
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-35-B
Bourns Inc.

GDT 350V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock18 300
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-60-B
Bourns Inc.

GDT 600V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock15 072
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2095-80-BLF
Bourns Inc.

GDT 800V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 800V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock20 400
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2031-42T-SMLF
Bourns Inc.

GDT 360V 1KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 360V
  • Impulse Discharge Current (8/20µs): 1000A (1kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock23 328
1000A (1kA)
-
2
No
Surface Mount
2-SMD Cylinder Square End
2035-15-B5
Bourns Inc.

GDT 150V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock13 776
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2089-160-BLF
Bourns Inc.

GDT 1600V 20% 1.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1600V
  • Impulse Discharge Current (8/20µs): 1500A (1.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock20 472
1500A (1.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2045-47-BLF
Bourns Inc.

GDT 470V 30% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±30%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock10 320
10000A (10kA)
±30%
2
No
Through Hole
Axial Cylinder
2026-07-C2
Bourns Inc.

GDT 75V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 75V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock8 712
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-07-B3LF
Bourns Inc.

GDT 75V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 75V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock18 456
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2027-23-BLF
Bourns Inc.

GDT 230V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock7 692
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-47-B
Bourns Inc.

GDT 470V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock11 388
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2095-250-BLF
Bourns Inc.

GDT 2500V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 2500V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock19 200
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2027-25-BLF
Bourns Inc.

GDT 250V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock19 860
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-35-BLF
Bourns Inc.

GDT 350V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock21 576
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder