Page 41 - Produits Bourns Inc. - Tubes à éclateur à gaz (GDT) | Heisener Electronics
Contactez nous
SalesDept@heisener.com 86-755-83210559-802
Language Translation

* Please refer to the English Version as our Official Version.

Produits Bourns Inc. - Tubes à éclateur à gaz (GDT)

Dossiers 1 289
Page  41/47
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
2035-23-C
Bourns Inc.

GDT 230V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock2 790
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-20-C
Bourns Inc.

GDT 200V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock3 600
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-15-C
Bourns Inc.

GDT 150V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock6 282
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-09-C5
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock8 946
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2035-09-C
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock4 032
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2097-220-DLF
Bourns Inc.

GDT 2200V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 2200V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock7 020
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
2097-100-DLF
Bourns Inc.

GDT 1000V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1000V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock2 772
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
2097-200-DLF
Bourns Inc.

GDT 2000V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 2000V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock2 340
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
2097-140-DLF
Bourns Inc.

GDT 1400V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1400V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock2 016
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
2097-120-DLF
Bourns Inc.

GDT 1200V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1200V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock6 606
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
2063-80-ALF
Bourns Inc.

GDT 800V 20% 60KA

  • Voltage - DC Spark Over (Nom): 800V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock6 516
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-60-ALF
Bourns Inc.

GDT 600V 20% 60KA

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock2 988
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-47-ALF
Bourns Inc.

GDT 470V 20% 60KA

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 416
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-35-ALF
Bourns Inc.

GDT 350V 20% 60KA

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 780
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-23-ALF
Bourns Inc.

GDT 230V 20% 60KA

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 312
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-70-ALF
Bourns Inc.

GDT 700V 20% 60KA

  • Voltage - DC Spark Over (Nom): 700V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock2 232
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-42-ALF
Bourns Inc.

GDT 420V 20% 60KA

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock2 628
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-25-ALF
Bourns Inc.

GDT 250V 20% 60KA

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock5 670
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-60-ALF
Bourns Inc.

GDT 600V 20% 40KA

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock4 482
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-47-ALF
Bourns Inc.

GDT 470V 20% 40KA

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 830
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-42-ALF
Bourns Inc.

GDT 420V 20% 40KA

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock5 220
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-35-ALF
Bourns Inc.

GDT 350V 20% 40KA

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock5 724
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-23-ALF
Bourns Inc.

GDT 230V 20% 40KA

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 830
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-80-ALF
Bourns Inc.

GDT 800V 20% 40KA

  • Voltage - DC Spark Over (Nom): 800V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 834
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-70-ALF
Bourns Inc.

GDT 700V 20% 40KA

  • Voltage - DC Spark Over (Nom): 700V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock4 950
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-30-ALF
Bourns Inc.

GDT 300V 20% 40KA

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 704
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-25-ALF
Bourns Inc.

GDT 250V 20% 40KA

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock2 178
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2047-35-BNI
Bourns Inc.

GDT 350V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock7 398
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend