Page 400 - Capteurs optiques - Photoélectriques, industriels | Capteurs, transducteurs | Heisener Electronics
Contactez nous
SalesDept@heisener.com +86-755-83210559 ext. 813
Language Translation

* Please refer to the English Version as our Official Version.

Capteurs optiques - Photoélectriques, industriels

Dossiers 11 325
Page  400/405
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Sensing Distance
Voltage - Supply
Response Time
Output Configuration
Connection Method
Ingress Protection
Cable Length
Light Source
Adjustment Type
Operating Temperature
MS4800S-30-1240-30X-50R
Omron Automation and Safety

SAFETY LIGHT CURTAIN SYSTEM

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock7 362
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MS4800S-14-0960-15X-15R
Omron Automation and Safety

SAFETY LIGHT CURTAIN SYSTEM

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock8 910
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MS46-14-1130-Q1-X
Omron Automation and Safety

SPARE TRANSMITTER

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 222
-
-
-
-
-
-
-
-
-
-
MS46SR-30-520-Q2-00X-00R-NC-FP
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock8 856
-
-
-
-
-
-
-
-
-
-
MS46SR-30-700-Q2-10X-15R-NC-FP
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock5 670
-
-
-
-
-
-
-
-
-
-
MS46SR-14-520-Q1-00X-00R-NC-AN
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock8 910
-
-
-
-
-
-
-
-
-
-
MS46SR-20-610-Q1-15X-10R-NO-FN
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock8 136
-
-
-
-
-
-
-
-
-
-
MS46LR-20-520-Q1-15X-15R-NC-FP
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock2 412
-
-
-
-
-
-
-
-
-
-
E3S-R2E43
Omron Automation and Safety

SENSOR OPTO REFL 2M PREWIRED MOD

  • Sensing Method: Retroreflective
  • Sensing Distance: 78.740" (2m)
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 1ms
  • Output Configuration: NPN - Dark-ON/Light-ON - Selectable
  • Connection Method: Cable
  • Ingress Protection: NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
  • Cable Length: -
  • Light Source: Infrared
  • Adjustment Type: Adjustable
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock8 010
78.740" (2m)
12 V ~ 24 V
1ms
NPN - Dark-ON/Light-ON - Selectable
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
-
Infrared
Adjustable
-25°C ~ 55°C
E3S-5DE4 5M
Omron Automation and Safety

DETECTOR

  • Sensing Method: Through-Beam
  • Sensing Distance: 196.850" (5m)
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 3ms
  • Output Configuration: NPN - Dark-ON/Light-ON - Selectable
  • Connection Method: Cable
  • Ingress Protection: NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
  • Cable Length: -
  • Light Source: Infrared
  • Adjustment Type: -
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock7 704
196.850" (5m)
12 V ~ 24 V
3ms
NPN - Dark-ON/Light-ON - Selectable
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
-
Infrared
-
-25°C ~ 55°C
70156-2495
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 924
-
-
-
-
-
-
-
-
-
-
70156-3678
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 312
-
-
-
-
-
-
-
-
-
-
70156-3899
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock8 910
-
-
-
-
-
-
-
-
-
-
70156-4331
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 490
-
-
-
-
-
-
-
-
-
-
F3SJ-A1487P14
Omron Automation and Safety

F3SJ-A1487P14

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock2 250
-
-
-
-
-
-
-
-
-
-
70156-3671
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock7 218
-
-
-
-
-
-
-
-
-
-
MS4800S-30-1640
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock2 844
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MSF4800S-40-0360-30-0240-10X-1
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock6 894
-
-
-
-
-
-
-
-
-
-
MS4800S-14-0320-10X-10R-RM3
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock3 132
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
SF4B-H88(V2)
Panasonic Industrial Automation Sales

LIGHT CURTAIN HAND 1750MM

  • Sensing Method: -
  • Sensing Distance: 11.811" ~ 275.59" (300mm ~ 7m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: NPN/PNP
  • Connection Method: Connector
  • Ingress Protection: IP65/67 - Dust Tight, Water Resistant, Waterproof
  • Cable Length: -
  • Light Source: Infrared
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock7 146
11.811" ~ 275.59" (300mm ~ 7m)
24V
14ms
NPN/PNP
Connector
IP65/67 - Dust Tight, Water Resistant, Waterproof
-
Infrared
-
-10°C ~ 55°C
MS4800S-14-0960-R
Omron Automation and Safety

RECEIVER SAFETY LIGHT CURTAIN

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock6 390
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
F3SJ-B0705P25
Omron Automation and Safety

F3SJ-B0705P25

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock7 380
-
-
-
-
-
-
-
-
-
-
PA46-3-400-Q2-NO1-NP-M
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock8 298
-
-
-
-
-
-
-
-
-
-
E3S-AD23
Omron Automation and Safety

SENS OPTO REFL 100MM PREWIRE MOD

  • Sensing Method: Reflective, Diffuse
  • Sensing Distance: 3.937" (100mm)
  • Voltage - Supply: 10 V ~ 30 V
  • Response Time: 500µs
  • Output Configuration: NPN - Dark-ON/Light-ON - Selectable
  • Connection Method: Cable
  • Ingress Protection: NEMA 4X; IEC IP67
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: Two-Turn Endless Adjuster with an Indicator
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock5 004
3.937" (100mm)
10 V ~ 30 V
500µs
NPN - Dark-ON/Light-ON - Selectable
Cable
NEMA 4X; IEC IP67
-
Infrared (880nm)
Two-Turn Endless Adjuster with an Indicator
-25°C ~ 55°C
MQ-W3C-DC12-24V-EM
Panasonic Industrial Automation Sales

AREA REFL PNP 3CM WIRE SEL 2MS

  • Sensing Method: Reflective
  • Sensing Distance: 1.575" (40mm)
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 2ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable
  • Ingress Protection: IP67
  • Cable Length: 78.740" (2000.00mm)
  • Light Source: Infrared
  • Adjustment Type: Adjustable
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock3 492
1.575" (40mm)
12 V ~ 24 V
2ms
PNP - Open Collector
Cable
IP67
78.740" (2000.00mm)
Infrared
Adjustable
-25°C ~ 55°C
E3Z-D82-G0SHW-CN
Omron Automation and Safety

SENSOR PHOTOELECTRIC 1M M8

  • Sensing Method: Reflective, Diffuse
  • Sensing Distance: 39.370" (1m)
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 1ms
  • Output Configuration: PNP - Dark-ON/Light-ON - Selectable
  • Connection Method: Cable
  • Ingress Protection: IEC IP67
  • Cable Length: -
  • Light Source: Infrared (860nm)
  • Adjustment Type: Single-Turn
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock2 898
39.370" (1m)
12 V ~ 24 V
1ms
PNP - Dark-ON/Light-ON - Selectable
Cable
IEC IP67
-
Infrared (860nm)
Single-Turn
-25°C ~ 55°C
E3Z-R81-G0SRW-P2
Omron Automation and Safety

SENSOR PHOTOELECTRIC 4M

  • Sensing Method: Retroreflective
  • Sensing Distance: 3.937" ~ 157.480" (100mm ~ 4m) ADJ
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 1ms
  • Output Configuration: PNP - Dark-ON/Light-ON - Selectable
  • Connection Method: Cable
  • Ingress Protection: IEC IP67, IP69K
  • Cable Length: -
  • Light Source: Infrared (660nm)
  • Adjustment Type: Single-Turn
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock6 966
3.937" ~ 157.480" (100mm ~ 4m) ADJ
12 V ~ 24 V
1ms
PNP - Dark-ON/Light-ON - Selectable
Cable
IEC IP67, IP69K
-
Infrared (660nm)
Single-Turn
-25°C ~ 55°C
LS-H91F
Panasonic Industrial Automation Sales

SENSOR HEAD RETRO REF FDA

  • Sensing Method: Retroreflective
  • Sensing Distance: 0.328" ~ 16.404' (10mm ~ 5m) ADJ
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: Cable
  • Ingress Protection: IP40
  • Cable Length: 78.740" (2000.00mm)
  • Light Source: Red Laser Diode (650nm)
  • Adjustment Type: Adjustable
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock4 878
0.328" ~ 16.404' (10mm ~ 5m) ADJ
-
-
-
Cable
IP40
78.740" (2000.00mm)
Red Laser Diode (650nm)
Adjustable
-10°C ~ 55°C