Page 27 - Capteurs optiques - Photoélectriques, industriels | Capteurs, transducteurs | Heisener Electronics
Contactez nous
SalesDept@heisener.com +86-755-83210559 ext. 803
Language Translation

* Please refer to the English Version as our Official Version.

Capteurs optiques - Photoélectriques, industriels

Dossiers 11 325
Page  27/405
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Sensing Distance
Voltage - Supply
Response Time
Output Configuration
Connection Method
Ingress Protection
Cable Length
Light Source
Adjustment Type
Operating Temperature
MS4800S-20-1240-50X-15R
Omron Automation and Safety

SAFETY LIGHT CURTAIN SYSTEM

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock3 330
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MS46SR-20-435-Q2-10X-10R-NO-FP
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock2 322
-
-
-
-
-
-
-
-
-
-
MS46SR-14-870-Q1-10X-10R-NC-FN
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock7 452
-
-
-
-
-
-
-
-
-
-
MS46LR-20-435-Q1-10X-10R-NC-FN
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 852
-
-
-
-
-
-
-
-
-
-
70156-1600
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 114
-
-
-
-
-
-
-
-
-
-
70156-3987
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock4 572
-
-
-
-
-
-
-
-
-
-
70156-4670
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock5 760
-
-
-
-
-
-
-
-
-
-
70156-4153
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 258
-
-
-
-
-
-
-
-
-
-
MSF4800S-14-1360-14-0320-10X-1
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock7 650
-
-
-
-
-
-
-
-
-
-
MSF4800A-30-1240-30-0600-10X-1
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock6 282
-
-
-
-
-
-
-
-
-
-
MSF4800S-20-1640-10X-10R-RM2AP
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock2 718
-
-
-
-
-
-
-
-
-
-
MSF4800S-20-0800-10X-10R-RM610
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock4 230
-
-
-
-
-
-
-
-
-
-
MSF4800B-14-0960
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock6 930
-
-
-
-
-
-
-
-
-
-
F3SJ-B1185P25
Omron Automation and Safety

F3SJ-B1185P25

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock5 220
-
-
-
-
-
-
-
-
-
-
MSF4800A-14-0320
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 204
-
-
-
-
-
-
-
-
-
-
MS4800B-20-0320-Q2-10X-10R
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock4 734
-
-
-
-
-
-
-
-
-
-
PA46-2-600-NO1-PN-M
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock6 012
-
-
-
-
-
-
-
-
-
-
PA46-3-500-Q2-NC2-PN-R
Omron Automation and Safety

SPARE RECEIVER

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock2 916
-
-
-
-
-
-
-
-
-
-
F3SJ-A0300P25-TS
Omron Automation and Safety

F3SJ-A0300P25-TS

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock8 190
-
-
-
-
-
-
-
-
-
-
PA46-BB-2-600-A-NC2-PN
Omron Automation and Safety

SPARE BOUNCE-BACK ACTIVE UNIT

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 960
-
-
-
-
-
-
-
-
-
-
E32-T14F
Omron Automation and Safety

SENS FIBER FLUORORESIN SIDEVIEW

  • Sensing Method: Through-Beam
  • Sensing Distance: 15.7" (40cm) 1.3'
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: Cable
  • Ingress Protection: IP67
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -40°C ~ 70°C
paquet: -
Stock3 562
15.7" (40cm) 1.3'
-
-
-
Cable
IP67
-
-
-
-40°C ~ 70°C
MC47WS-KT-150
Omron Automation and Safety

MC47 WELD SHIELD 150MM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock2 340
-
-
-
-
-
-
-
-
-
-
FT-45X-2T
Panasonic Industrial Automation Sales

FT-45X WITH 2M FIBER CABLE

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock2 952
-
-
-
-
-
-
-
-
-
-
E3T-SR22 2M
Omron Automation and Safety

SENS OPTO REFL 200MM PREWIRE MOD

  • Sensing Method: Retroreflective
  • Sensing Distance: 7.874" (200mm)
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 1ms
  • Output Configuration: NPN - Open Collector/Dark-ON
  • Connection Method: Cable
  • Ingress Protection: IEC IP67
  • Cable Length: -
  • Light Source: Infrared (650nm)
  • Adjustment Type: -
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock3 114
7.874" (200mm)
12 V ~ 24 V
1ms
NPN - Open Collector/Dark-ON
Cable
IEC IP67
-
Infrared (650nm)
-
-25°C ~ 55°C
CX-424-P-C5
Panasonic Industrial Automation Sales

SENSOR PHOTO 100MM 12-24VDC PNP

  • Sensing Method: Reflective, Diffuse
  • Sensing Distance: 3.937" (100mm)
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 1ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable
  • Ingress Protection: IP67
  • Cable Length: 78.740" (2000.00mm)
  • Light Source: Infrared (860nm)
  • Adjustment Type: -
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock6 282
3.937" (100mm)
12 V ~ 24 V
1ms
PNP - Open Collector
Cable
IP67
78.740" (2000.00mm)
Infrared (860nm)
-
-25°C ~ 55°C
E3FB-DN22
Omron Automation and Safety

BRASSM18,0.3M DIFF,AX,NPN,CONN

  • Sensing Method: Reflective, Diffuse
  • Sensing Distance: 11.811" (300mm)
  • Voltage - Supply: 10 V ~ 30 V
  • Response Time: 500µs
  • Output Configuration: NPN - Dark-ON/Light-ON - Selectable
  • Connection Method: Connector, M12
  • Ingress Protection: IEC IP67, IP69K
  • Cable Length: -
  • Light Source: Red LED
  • Adjustment Type: Single-Turn
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock7 200
11.811" (300mm)
10 V ~ 30 V
500µs
NPN - Dark-ON/Light-ON - Selectable
Connector, M12
IEC IP67, IP69K
-
Red LED
Single-Turn
-25°C ~ 55°C
CY-122VA
Panasonic Industrial Automation Sales

SENSOR PHOTO NPN 600MM 12-24V

  • Sensing Method: Reflective, Diffuse
  • Sensing Distance: 23.6" (60cm) 2.0'
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 1ms
  • Output Configuration: NPN - Open Collector
  • Connection Method: Cable
  • Ingress Protection: IP67
  • Cable Length: 80.0" (200cm)
  • Light Source: Infrared
  • Adjustment Type: Adjustable
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock4 302
23.6" (60cm) 2.0'
12 V ~ 24 V
1ms
NPN - Open Collector
Cable
IP67
80.0" (200cm)
Infrared
Adjustable
-25°C ~ 55°C
FT-V24W
Panasonic Industrial Automation Sales

FIBER 2MM NON-THREAD THRUBEAM R1

  • Sensing Method: Through-Beam
  • Sensing Distance: 4.331" (110mm)
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: Cable
  • Ingress Protection: -
  • Cable Length: 78.740" (2000.00mm)
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock4 788
4.331" (110mm)
-
-
-
Cable
-
78.740" (2000.00mm)
-
-
-