Page 205 - Capteurs optiques - Photoélectriques, industriels | Capteurs, transducteurs | Heisener Electronics
Contactez nous
SalesDept@heisener.com +86-755-83210559 ext. 813
Language Translation

* Please refer to the English Version as our Official Version.

Capteurs optiques - Photoélectriques, industriels

Dossiers 11 325
Page  205/405
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Sensing Distance
Voltage - Supply
Response Time
Output Configuration
Connection Method
Ingress Protection
Cable Length
Light Source
Adjustment Type
Operating Temperature
MS4800S-30-0880-00X-00R
Omron Automation and Safety

SAFETY LIGHT CURTAIN SYSTEM

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock5 634
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MS46SR-20-260-Q2-R-NO-FP
Omron Automation and Safety

SPARE RECEIVER

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock6 246
-
-
-
-
-
-
-
-
-
-
MS46LR-30-1570-Q2-10X-15R-NO-F
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock7 758
-
-
-
-
-
-
-
-
-
-
MS46LR-30-1745-Q2-15X-15R-NO-A
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock6 948
-
-
-
-
-
-
-
-
-
-
MS46LR-30-870-Q1-10X-10R-NO-FP
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock7 902
-
-
-
-
-
-
-
-
-
-
MS46SR-14-350-Q2-30X-30R-NC-FN
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock4 320
-
-
-
-
-
-
-
-
-
-
MS46SR-20-785-Q1-10X-10R-NO-FN
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 222
-
-
-
-
-
-
-
-
-
-
E3JK-5M1-N-US
Omron Automation and Safety

CUL, T-B, L-ON, AC/DC VOLTS

  • Sensing Method: Through-Beam
  • Sensing Distance: 196.850" (5m)
  • Voltage - Supply: 24 ~ 240VAC, 12 ~ 240VDC
  • Response Time: 30ms
  • Output Configuration: Relay - Light-ON
  • Connection Method: Cable
  • Ingress Protection: IEC IP64
  • Cable Length: -
  • Light Source: Infrared (950nm)
  • Adjustment Type: Fixed
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock7 650
196.850" (5m)
24 ~ 240VAC, 12 ~ 240VDC
30ms
Relay - Light-ON
Cable
IEC IP64
-
Infrared (950nm)
Fixed
-25°C ~ 55°C
E3F2-R4C4-M1-M-E
Omron Automation and Safety

SENSOR RETROREFLECT NPN M12 METL

  • Sensing Method: Retroreflective, Polarized
  • Sensing Distance: 3.937" ~ 157.480" (100mm ~ 4m) ADJ
  • Voltage - Supply: 10 V ~ 30 V
  • Response Time: 1ms
  • Output Configuration: NPN - Open Collector
  • Connection Method: Connector
  • Ingress Protection: NEMA 6
  • Cable Length: -
  • Light Source: Infrared
  • Adjustment Type: Fixed
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock5 364
3.937" ~ 157.480" (100mm ~ 4m) ADJ
10 V ~ 30 V
1ms
NPN - Open Collector
Connector
NEMA 6
-
Infrared
Fixed
-25°C ~ 55°C
70156-3746
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock2 124
-
-
-
-
-
-
-
-
-
-
70156-2291
Omron Automation and Safety

SYSTEM

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock4 986
-
-
-
-
-
-
-
-
-
-
MS4800S-20-1760-10X-10R
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock5 328
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MS4800S-30-1680-10X-10R
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock8 154
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MS4800S-14-1280-10X-10R
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock6 174
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MSF4800-30-1880-XR2
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock7 920
-
-
-
-
-
-
-
-
-
-
MS4800S-20-1240-30X-30R
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: Through-Beam
  • Sensing Distance: 787.4" (20m)
  • Voltage - Supply: 24V
  • Response Time: 14ms
  • Output Configuration: PNP - Open Collector
  • Connection Method: Cable with Connector
  • Ingress Protection: IP65
  • Cable Length: -
  • Light Source: Infrared (880nm)
  • Adjustment Type: -
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock2 052
787.4" (20m)
24V
14ms
PNP - Open Collector
Cable with Connector
IP65
-
Infrared (880nm)
-
-10°C ~ 55°C
MS4800B-30-1640
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 348
-
-
-
-
-
-
-
-
-
-
MS4800B-20-0920-15X-10R
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock4 212
-
-
-
-
-
-
-
-
-
-
MSF4800-40-1200-XR2
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock4 068
-
-
-
-
-
-
-
-
-
-
MSF4800A-40-0600-10X-10R-RM610
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 474
-
-
-
-
-
-
-
-
-
-
MSF4800-30-0840-XR2
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock7 668
-
-
-
-
-
-
-
-
-
-
F3SJ-A0461P14
Omron Automation and Safety

F3SJ-A0461P14

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 366
-
-
-
-
-
-
-
-
-
-
MS4800A-30-0440-10X-10R
Omron Automation and Safety

SAFETY LIGHT CURTAIN

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock3 834
-
-
-
-
-
-
-
-
-
-
F3SJ-A0371P14
Omron Automation and Safety

F3SJ-A0371P14

  • Sensing Method: -
  • Sensing Distance: -
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: -
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock6 390
-
-
-
-
-
-
-
-
-
-
FD-H35-M2S6
Panasonic Industrial Automation Sales

FIBER HEART-RESIST (-76-662F)

  • Sensing Method: Reflective
  • Sensing Distance: 10.236" (260mm)
  • Voltage - Supply: -
  • Response Time: -
  • Output Configuration: -
  • Connection Method: Cable
  • Ingress Protection: -
  • Cable Length: 78.740" (2000.00mm)
  • Light Source: -
  • Adjustment Type: -
  • Operating Temperature: -
paquet: -
Stock5 436
10.236" (260mm)
-
-
-
Cable
-
78.740" (2000.00mm)
-
-
-
FX-301-F7
Panasonic Industrial Automation Sales

SENSOR FIBER AMP NPN 12-24VDC

  • Sensing Method: Through-Beam
  • Sensing Distance: -
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 2ms
  • Output Configuration: NPN - Open Collector
  • Connection Method: Connector
  • Ingress Protection: -
  • Cable Length: -
  • Light Source: Red LED
  • Adjustment Type: Adjustable
  • Operating Temperature: -10°C ~ 55°C
paquet: -
Stock8 874
-
12 V ~ 24 V
2ms
NPN - Open Collector
Connector
-
-
Red LED
Adjustable
-10°C ~ 55°C
E3T-ST12-D
Omron Automation and Safety

RECEIVER ONLY, SIDE MOUNT 2M C

  • Sensing Method: Through-Beam
  • Sensing Distance: 39.370" (1m)
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 1ms
  • Output Configuration: NPN - Open Collector/Dark-ON
  • Connection Method: Cable
  • Ingress Protection: IEC IP67
  • Cable Length: -
  • Light Source: Infrared (650nm)
  • Adjustment Type: Adjustable
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock7 704
39.370" (1m)
12 V ~ 24 V
1ms
NPN - Open Collector/Dark-ON
Cable
IEC IP67
-
Infrared (650nm)
Adjustable
-25°C ~ 55°C
CX-422-Z
Panasonic Industrial Automation Sales

SENSOR PHOTO 800MM 12-24VDC NPN

  • Sensing Method: Reflective, Diffuse
  • Sensing Distance: 31.496" (800mm)
  • Voltage - Supply: 12 V ~ 24 V
  • Response Time: 1ms
  • Output Configuration: NPN - Open Collector
  • Connection Method: Cable
  • Ingress Protection: IP67
  • Cable Length: 78.740" (2000.00mm)
  • Light Source: Infrared (860nm)
  • Adjustment Type: -
  • Operating Temperature: -25°C ~ 55°C
paquet: -
Stock4 104
31.496" (800mm)
12 V ~ 24 V
1ms
NPN - Open Collector
Cable
IP67
78.740" (2000.00mm)
Infrared (860nm)
-
-25°C ~ 55°C