Tubes à éclateur à gaz (GDT)

Dossiers 2 953
Page  89/99
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
SL1024A600RG
Littelfuse Inc.

GDT 600V 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock3 258
10000A (10kA)
-
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
GTCT37-251M-P10
Littelfuse Inc.

GDT 250V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
paquet: Axial Cylinder, 3 Lead (T-Shape)
Stock7 344
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
GTCR38-251M-Q10
Littelfuse Inc.

GDT 250V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Radial Cylinder, 3 Lead
paquet: Radial Cylinder, 3 Lead
Stock8 640
10000A (10kA)
±20%
3
No
Through Hole
Radial Cylinder, 3 Lead
SL1024B500C
Littelfuse Inc.

GDT 500V 20KA

  • Voltage - DC Spark Over (Nom): 500V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
paquet: Cylinder No Lead, 3 Terminal
Stock2 286
20000A (20kA)
-
3
No
User Defined
Cylinder No Lead, 3 Terminal
SL1024A400C
Littelfuse Inc.

GDT 400V 10KA

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
paquet: Cylinder No Lead, 3 Terminal
Stock4 086
10000A (10kA)
-
3
No
User Defined
Cylinder No Lead, 3 Terminal
SL1021A145RS
Littelfuse Inc.

GDT 145V 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 145V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock6 660
10000A (10kA)
-
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
SA2-7200-DBB-STD
Bourns Inc.

GDT 7200V -15%, +20% 5KA T/H

  • Voltage - DC Spark Over (Nom): 7200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -15%, +20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock6 282
5000A (5kA)
-15%, +20%
2
No
Through Hole
Axial Cylinder, Radial Bend
AC240
Littelfuse Inc.

GDT 600V 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock7 200
5000A (5kA)
-
2
No
Through Hole
Axial Cylinder
2026-42-C3FLF
Bourns Inc.

GDT 420V 20% 20KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock7 884
20000A (20kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2026-09-C3FLF
Bourns Inc.

GDT 90V 20% 20KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock4 860
20000A (20kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-30-B2F
Bourns Inc.

GDT 300V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock8 118
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
SL1411A350C
Littelfuse Inc.

GDT 350V 10KA

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 600
10000A (10kA)
-
2
No
User Defined
Cylinder No Lead
2038-35-SM
Bourns Inc.

GDT 350V 25% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±25%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock5 904
5000A (5kA)
±25%
3
No
Surface Mount
3-SMD Cylinder Square End
2026-30-C18
Bourns Inc.

GDT 300V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock3 400
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2026-25-C18
Bourns Inc.

GDT 250V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock4 140
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2026-15-C18
Bourns Inc.

GDT 150V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock7 488
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2026-15-A1
Bourns Inc.

GDT 150V 20% 20KA

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
paquet: Cylinder No Lead, 3 Terminal
Stock4 500
20000A (20kA)
±20%
3
No
User Defined
Cylinder No Lead, 3 Terminal
B88069X4570T103
EPCOS (TDK)

GDT 510V 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 510V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock3 526
10000A (10kA)
-
2
No
Through Hole
Axial Cylinder
2095-600-CLF
Bourns Inc.

GDT 6000V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 6000V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock5 058
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2027-47-A
Bourns Inc.

GDT 470V 15% 10KA

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 452
10000A (10kA)
±15%
2
No
User Defined
Cylinder No Lead
2027-40-SMLF
Bourns Inc.

GDT 400V 15% 10KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock7 038
10000A (10kA)
±15%
2
No
Surface Mount
2-SMD Cylinder Square End
2037-30-B
Bourns Inc.

GDT 300V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock2 988
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-47-SM-RP
Bourns Inc.

GDT 470V 15% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock8 388
5000A (5kA)
±15%
2
No
Surface Mount
2-SMD Cylinder Square End
2039-110-ALF
Bourns Inc.

GDT 1100V 20% 2.5KA

  • Voltage - DC Spark Over (Nom): 1100V
  • Impulse Discharge Current (8/20µs): 2500A (2.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 834
2500A (2.5kA)
±20%
2
No
User Defined
Cylinder No Lead
2036-15-BLF
Bourns Inc.

GDT 150V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock19 224
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, Radial Bend
SA2-6200-CLT-STD
Bourns Inc.

GDT 6200V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 6200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock4 482
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
SL1026-400
Littelfuse Inc.

GDT 400V 20KA HOLDER

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Holder
  • Package / Case: Cartridge
paquet: Cartridge
Stock8 928
20000A (20kA)
-
3
No
Holder
Cartridge
B88069X8690B502
EPCOS (TDK)

GDT 350V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock14 424
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2038-110-SM-RPLF
Bourns Inc.

GDT 1100V 25% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 1100V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±25%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock26 184
5000A (5kA)
±25%
3
No
Surface Mount
3-SMD Cylinder Square End
2039-80-SM-RPLF
Bourns Inc.

GDT 800V 20% 2.5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 800V
  • Impulse Discharge Current (8/20µs): 2500A (2.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock72 732
2500A (2.5kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End